鑫鑫医疗
LABSTAR240 Automated Blood Culture System
Fully automatic benchtop biochemistry analyzer delivering 480 tests/hour with dual-reaction-zone optics, 60 reagent positions, and 2-35 uL sample volume for mid-volume clinical labs.
Highlights
- 480 tests/hour throughput for mid-volume lab workloads
- Dual-reaction-zone optical path runs endpoint and kinetic assays in parallel
- 2-35 uL sample volume range supports pediatric and limited-volume specimens
- 60 reagent positions with 2-8 degrees Celsius on-board cooling
- Barcode primary-tube sampling for direct phlebotomy rack loading
- STAT sample interrupt for urgent specimens without stopping the batch
- Eight-wavelength photometer 340-800 nm with carryover below 0.1 percent
- CE Marked and manufactured under ISO 13485 quality management system
Technical Dossier
| Throughput | 480 Tests/Hour |
|---|---|
| Sample Volume | 2-35 uL |
| Reagent Positions | 60 On-Board |
| Reaction Zones | Dual Reaction Zone |
| Wavelengths | 340-800 nm, 8 Channels |
| Photometric Range | 0-3.0 ABS |
| Carryover | Less Than 0.1 Percent |
| Reagent Cooling | 2-8 Degrees Celsius |
| Sample Input | Barcoded Primary Tube |
| Certification | CE Marked, ISO 13485 |
| QC Software | Westgard Multi-Rule |
| Reagent Shelf Life | 18 Months |
Product Detail
Overview
Need a mid-volume biochemistry analyzer? XX-200 does 480 tests/hour. It is a bench-top model. Good for hospitals with 200-800 samples per day. Also works for regional labs and contract research labs. Runs routine chemistries and specific protein assays.
It has a dual-reaction-zone optical path. Runs endpoint and kinetic assays in parallel. This cuts turnaround time for mixed test panels. Supports barcoded primary tubes. Phlebotomy samples go straight to the rack. No pre-aliquoting needed.
Throughput480 tests/hour
Sample Volume2-35 uL
Reagent Positions60 on board
Reaction CuvettesDual-reaction-zone
Dual-Reaction-Zone Design for Mid-Volume Labs
Most bench analyzers use one cuvette train. XX-200 splits reaction path into two zones. Two chemistries incubate and photometer at same time. For mixed panels, scheduler overlaps incubation windows. No queuing.
Run 50 samples with 12 chemistries each. Last result comes earlier. Good for same-day outpatient reports. Helps with emergency department turnaround.
Sample Handling and Volume Range
Sample volume is 2-35 uL. Covers pediatric and geriatric draws. Minimum 2 uL dead-space. Probe can collect serum from a 150 uL pediatric capillary tube after centrifugation.
Primary tube sampling with barcode recognition. Direct rack loading from phlebotomy.
Automatic pre-dilution for high-concentration samples. No manual rerun steps.
Sample probe has inner-wall wash and outer-wall wipe. Carryover is below 0.1 percent.
STAT sample interrupt. Urgent specimens jump the queue. No need to stop the running batch.
Reagent Management
On-board reagent disk holds 60 positions. Cooling is 2-8 degrees Celsius. Open-reagent stability tracking records load date. Flags bottles near expiration. Helps avoid wasted reagent.
Reagent blanks run automatically on first use. Recalibration is user-configurable. System accepts third-party reagent parameters. Not locked into one supplier.
Photometric Performance
Optical system uses halogen source. Eight wavelengths from 340 to 800 nm. Absorbance linearity up to 3.0 ABS. Photometric repeatability is CV less than 1 percent. Confirm these figures with your QC material during installation.
Quality Control and Traceability
QC software uses Westgard multi-rule logic. Stores Levey-Jennings charts for each analyte. Flags runs that breach user-set rules. QC data stays on internal drive. Export as CSV for LIS or audit.
System has CE Marking. Made under ISO 13485. Buyers needing FDA 510(k) or local registration should confirm status before purchase.
Pre-purchase confirmation: Check reagent compatibility with open-channel brands. Confirm FDA status for US. Ask about installation language options. These vary by destination. Not in the spec alone.
Procurement and Selection Guidance
Matching Throughput to Your Lab Workflow
480 tests/hour suits 200-800 samples per day. Panels of 10-20 analytes per sample. Daily volume over 800? Consider floor-standing model. Under 150 samples? 60 reagent positions may be underused.
Reagent Logistics Planning
Reagent shelf life is 18 months. On-board cooling is 2-8 degrees Celsius. Plan cold-chain logistics. Shipments from Nanjing need temperature control. Confirm pack sizes and MOQ with sales team.
Regulatory Documentation for Distributor Registration
Instrument is CE Marked. Made under ISO 13485. Documentation packages available for local approval. Registered or under registration in over 30 countries. Confirm status for your jurisdiction before ordering.

Manufactured by Xinxin Medical
Xinxin Medical is a diagnostics manufacturer. Founded in 2009. Has 6,000 m² facility in Nanjing. Class 100,000 cleanroom assembly lines. In-house calibration lab. Supplies hospitals, labs, and distributors in Southeast Asia, Middle East, Africa, and Latin America.
Reagent batches have double-blind QC testing. Analyzer optics validated against NIST standards. Registered or under registration in over 30 countries. Documentation packages support local approval.
Buyer Questions
What daily sample volume is XX-200 for?
480 tests/hour. For labs with 200 to 800 samples per day. Above that? Look at higher-throughput floor model.
Can I use third-party reagents?
Yes. System accepts user-programmed parameters on open channel. Lab must validate performance with chosen reagent brand. Do this during installation.
What is MOQ and lead time?
MOQ is 1 unit. Lead time is 15-25 working days after deposit. Depends on production schedule. Confirm exact time at inquiry.
Is installation support included?
Installation, training, and first-year maintenance through regional distributor. Remote commissioning support available. Confirm service coverage for your location.
What reagent shelf life? How to plan cold-chain?
Shelf life is 18 months. On-board cooling is 2-8 degrees Celsius. Shipping from Nanjing needs temperature control. Confirm pack sizes and cold-chain with sales team.
Does system support STAT samples?
Yes. STAT interrupt lets urgent specimens jump queue. No need to stop batch. Barcode primary-tube sampling. Load directly from phlebotomy tube.
What QC software is included?
Westgard multi-rule logic. Levey-Jennings charting for each analyte. Export QC data as CSV for LIS or audit. Rejection rules are user-configurable.
What documentation for local registration?
CE IVD docs and ISO 13485 records available. Registered or under registration in over 30 countries. Confirm package and status with sales team.
Request XX-200 Details